43 of 48 items assessed
Work is saved on this device as you go
Item identity
Where the item is and how it is identified.
Avoid capturing people — especially children or vulnerable individuals — and follow the site's safeguarding rules.
Item already has a code from an earlier survey? Scan it to link this item to that record. Otherwise a new code is generated when you save.
Give at least one of these — a location or a reference. It is how this item is found again on the next visit.
Substrate & services
What the item is installed in, and what runs through it.
Tested system used
Link the tested system this item was installed to.
BS EN 1366-3 · EI 120 — plastic pipes to Ø110 through concrete floors and masonry walls.
Item photos
The item as found. This photo model is set by the visit type (Survey) and stays the same for every item on this survey.
Photograph the item as found — both sides, any ID label, and any defect. Add as many as you need.
Result & severity
Mark the item pass, defective, fail or not applicable.
Review & save
Confirm the result, then save this item.
Riser 2 · Level 3, floor slab · P-016 — penetration seal in a concrete slab, intumescent collar on a 110mm soil stack.
Items
Items
Filter items
| Item | Status | Severity | System | Specs | Construction | Actions | |
|---|---|---|---|---|---|---|---|
| Riser 2 · Level 3, north wall Penetration seal · P-012 📍 Level 3 3 photos | Pass | — | EI 120 batt + ablative sealant | EI 120 · 400×300 · gap 20mm · depth 50mm | Wall · Plasterboard · Cable tray | ||
| Riser 2 · Level 3, east wall Penetration seal · P-014 📍 Level 3 3 photos Annular gap out of tolerance | Defective | High | Intumescent sealant | EI 60 · Ø54 · gap 38mm · depth 25mm | Wall · Blockwork · Copper pipe | ||
| Riser 2 · Level 3, riser wall Fire damper · P-015 📍 Level 3 3 photos | Pass | — | Fire damper + EI 120 batt | EI 120 · 600×400 · depth 60mm | Wall · Blockwork · HVAC duct | ||
| Riser 2 · Level 3, floor slab Penetration seal · P-016 📍 Level 3 | Awaiting this visit | — | — | EI 120 · Ø110 | Floor · Concrete slab · Soil stack (uPVC) | ||
| Comms shaft · Level 3, shaft wall Penetration seal · P-018 📍 Level 3 2 photos | Pass | — | Re-enterable fire pillows | EI 60 · 300×200 · depth 200mm | Wall · Shaft wall · Data cable bundle | ||
| Riser 2 · Level 3, south wall Penetration seal · P-019 📍 Level 3 2 photos | Pass | — | Acrylic intumescent sealant | EI 60 · Ø32 · gap 12mm · depth 25mm | Wall · Blockwork · Sprinkler pipe (steel) | ||
| Corridor C3 · Level 3, west wall Penetration seal · P-020 📍 Level 3 2 photos | Pass | — | High-movement silicone sealant | EI 60 · Ø25 · gap 10mm · depth 25mm | Wall · Plasterboard · Steel conduit | ||
| Riser 2 · Level 3, north wall (high level) Penetration seal · P-021 📍 Level 3 3 photos | Pass | — | EI 120 batt + ablative sealant | EI 120 · 450×150 · gap 25mm · depth 50mm | Wall · Blockwork · Cable basket | ||
| Riser 2 · Level 3, west wall Penetration seal · P-022 📍 Level 3 | Awaiting this visit | — | — | EI 120 · 150×150 | Wall · Blockwork · Cable bundle (LV) | ||
| Corridor C3 · Level 3, ceiling void Linear joint · P-029 📍 Level 3 Boxed in behind the new suspended ceiling — not visible | Not on site | — | — | EI 60 | Wall · Plasterboard · Head of wall | ||
| Riser 2 · Level 3, south wall (low level) Penetration seal · P-031 📍 Level 3 | Awaiting this visit | — | — | EI 120 · Ø54 | Wall · Blockwork · Copper pipe | ||
| Comms shaft · Level 3, floor slab Penetration seal · P-032 📍 Level 3 | Awaiting this visit | — | — | EI 120 · 300×200 | Floor · Concrete slab · Data cable bundle | ||
| Riser 2 · Level 3, riser door head Linear joint · P-049 📍 Level 3 2 photos Added on site | Pass | — | Acrylic intumescent sealant | EI 60 · joint 15mm | Wall · Blockwork · Head of wall |
Property layout
Add floorplans
Add as many plans as the building needs — 15 per upload, then repeat. Got every floor in one PDF? Upload it as it is — each sheet becomes its own plan, named from its title (up to 30 sheets).
Awaiting this visit Tagged Untagged Needs work
QR tags
QR tags
Filter items
| Item | Floorplan | Tag | UID | Last scan | Actions |
|---|---|---|---|---|---|
| Riser 2 · Level 3, north wall | Level 3 — Riser 2 | Tagged | FS-A8K2M |
19 Oct 2026 10:31 | |
| Riser 2 · Level 3, east wall | Level 3 — Riser 2 | Tagged | FS-B3N7P |
19 Oct 2026 13:36 | |
| Riser 2 · Level 3, riser wall | Level 3 — Riser 2 | Tagged | FS-E5J2Q |
19 Oct 2026 11:54 | |
| Riser 2 · Level 3, floor slab | Level 3 — Riser 2 | Tagged | FS-H2T6W |
Never scanned | |
| Riser 2 · Level 3, west wall | Level 3 — Riser 2 | Tagged | FS-J7C3N |
Never scanned | |
| Riser 2 · Level 3, riser door head | Level 3 — Riser 2 | Untagged | — | — | — |
| Comms shaft · Level 3, shaft wall | Level 3 — Corridors & shafts | Tagged | FS-F8L4R |
19 Oct 2026 14:20 | |
| Corridor C3 · Level 3, west wall | Level 3 — Corridors & shafts | Tagged | FS-K4P9D |
19 Oct 2026 15:02 | |
| Riser 2 · Level 3, south wall (low level) | Not on a plan | Tagged | FS-M9R2X |
Never scanned |